Motec ADR Manuel d'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
ADR Functionality User Manual ADR Functional Reference
Event Triggering
The readings from the three axes of the accelerometer pass through several levels of low pass filtering before being
used for triggering and logging.
Event Triggering can be set using the Device Configuration function; see the Events Tab section on page 7. The event
triggering flow is as shown below.
Analogue anti-aliasing filter
(400Hz 2
nd
order Bessel)
Software filter
(250Hz 4
th
order Butterworth)
User configurable trigger filter
(5Hz-100Hz 2
nd
order Butterworth)
Event triggering against user configurable
thresholds
d
Software filter for CFC60
100Hz 2
nd
order Butterworth
User configurable trigger filter
(5Hz-100Hz 2
nd
order Butterworth)
Log file containing:
Raw log readings
Log readings filtered to CFC60
Log readings filtered with the user configurable trigger filter
Event Log
ADR Device
PC (ADR Manager)
(400Hz 2
nd
order Bessel)
Accelerometer Internal filter
Figure 10 – Flow of Event Triggering
Event Triggering Methods
The ADR can be configured to use one of three event triggering methods:
The XYZ Vector is the recommended trigger method. A trigger method with separate Z axis settings can be useful in
situations where large Z axis accelerations such as curb impacts are expected.
Trigger on XYZ Vector
An event is triggered when the magnitude of the XYZ acceleration vector exceeds the Event Trigger Level.
The event is marked as a severe event when the magnitude of the XYZ acceleration vector exceeds the Severe Event
Trigger Level.
The same trigger filter settings are used for all axes.
MoTeC — Published: 11 February 2014 Page 14