Motec Interpreter Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Motec Interpreter. MoTeC Interpreter User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 37
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
M oTe C Interpreter User’s Manual
Introduction ........................................................................ 1
Welcome.............................................................................................................1
Additional Documentation ...................................................................................1
Overview ............................................................................. 3
System Logging Options and Accessories..........................................................3
Software Summary............................................................. 6
Software Navigation............................................................................................ 6
Preferences ........................................................................................................7
Printing................................................................................................................ 7
Acquiring Data.................................................................... 8
Dash/Logger .......................................................................................................8
Engine Management System M800/M880 .......................................................... 8
Engine Management System M4/48/M8 .............................................................9
Logging Modes ................................................................................................... 9
File Format........................................................................................................10
Vehicle Details .................................................................................................. 10
Channel Setup .................................................................................................. 10
Analysis Tools.................................................................. 13
Graphical Analysis ............................................................................................ 13
Track Map.........................................................................................................17
Mixture Map ...................................................................................................... 22
Mathematics .....................................................................................................23
Histogram .........................................................................................................27
Statistics ........................................................................................................... 29
Virtual Dash ...................................................................................................... 30
XY Graph ..........................................................................................................31
Appendix 1 Graph Hot Keys ........................................... 33
Cursor ............................................................................................................... 33
Components .....................................................................................................33
Zoom................................................................................................................. 34
General ............................................................................................................. 35
Vue de la page 0
1 2 3 4 5 6 ... 36 37

Résumé du contenu

Page 1

M oTe C Interpreter User’s Manual Introduction ... 1 Welcome...

Page 2 - 26 August, 2002

8 Acquiring Data Acquiring Data Data for analysis may be downloaded from a number of MoTeC products if the data logging option has been enabled. Th

Page 3 - Introduction

MoTeC Acquiring Data 9 Engine Management System M4/48/M8 Data is downloaded from the ECU via a MoTeC PC Interface cable attached to the serial port o

Page 4 - 2 Introduction

10 Acquiring Data Fastest Lap Logging is useful for fast recording of chassis channels, such as suspension position and force without quickly consumi

Page 5 - Overview

MoTeC Acquiring Data 11 necessary for the sensor to provide accurate data for display and analysis in MoTeC interpreter: G-Force Sensor A G force sen

Page 6 - Wideband Lambda Inputs

12 Acquiring Data 13" 14" 15" 16" 17" 18"2° 11.5 12.4 13.3 14.2 15.1 16.04°23.0 24.8 26.6 28.3 30.1 31.96°34.5 37.2 39.

Page 7 - Telemetry

MoTeC Analysis Tools 13 Analysis Tools Graphical Analysis Overview Graphical Analysis is a window depicting graphs of various parameters that were lo

Page 8 - Software Summary

14 Analysis Tools Graph Templates The format in which to display the log data is stored in a Graph template. The template determines where and how m

Page 9 - Printing

MoTeC Analysis Tools 15 channel, is displayed in the graph title. The “Data Box” displays the value of every logged channel at the current cursor loc

Page 10 - Acquiring Data

16 Analysis Tools Multiple Views If the main Interpreter window is run in a reduced size mode, it is possible to have multiple views displayed simult

Page 11 - Logging Modes

MoTeC Analysis Tools 17 Track Map Overview The Track Map is a graphical representation of a circuit, upon which data recorded during a vehicle outing

Page 12 - Channel Setup

 Copyright – Motec Pty Ltd – 1998-2002 The information in this document is subject to change without notice. While every effort is taken to ensur

Page 13 - Steered Angle

18 Analysis Tools However, if a new track map is to be calculated and drawn, some extra information must be logged. The necessary channels are:  S

Page 14 - Suspension Position

MoTeC Analysis Tools 19 Reports – Rainbow Map The Rainbow map is a representation of the value of a Channel at each point of a lap. The value of th

Page 15 - Analysis Tools

20 Analysis Tools Reports – Lap Map A lap map provides a lap by lap summary of vehicle performance, allowing visual determination of differences betw

Page 16 - Data Viewing

MoTeC Analysis Tools 21

Page 17 - Channel Units

22 Analysis Tools Mixture Map The mixture map function allows the user to analyze exhaust gas mixture strengths, over a wide range of load and rpm, t

Page 18 - Multiple Views

MoTeC Analysis Tools 23 Mathematics Allows for manipulation of data via a number of different functions. The main ‘Define Math Functions’ window is d

Page 19 - Track Map

24 Analysis Tools Defining a Math Function Select and highlight a blank line – they are numbered 1 through 60 - in either Default or Current File ma

Page 20 - 18 Analysis Tools

MoTeC Analysis Tools 25 Next, the type of measurement: voltage, temperature, pressure etc is selected, followed by the actual units for that measurem

Page 21 - Reports – Rainbow Map

26 Analysis Tools Standard and Pro Logging The following Math functions are available with Standard logging: Distance, Filter, Scale/Offset and Bike

Page 22 - Reports – Section Times

MoTeC Analysis Tools 27 Histogram To improve the efficiency of the tuning process a RPM histogram shows the relative time spent at any one rpm point

Page 23 - MoTeC Analysis Tools 21

MoTeC Introduction 1 Introduction Welcome Thank you for purchasing a MoTeC Data Acquisition and Analysis System. MoTeC provides a range of powerful

Page 24 - Mixture Map

28 Analysis Tools template has been defined, this feature can be used to examine the behaviour of channels over a certain section of the data. To ena

Page 25 - Mathematics

MoTeC Analysis Tools 29 Statistics The statistics screen shows a summary of the logged session, selectable by the logging type (Normal, Fastest, Burs

Page 26 - Defining a Math Function

30 Analysis Tools Virtual Dash You can re-drive any lap in real time with all logged channels available for viewing. This can be a useful tool for vi

Page 27 - Math Status

MoTeC Analysis Tools 31 XY Graph The XY Graph generates a scatter plot that allows for comparison of any parameter against any other parameter. It i

Page 29 - Histogram

MoTeC Appendices 33 Appendix 1 Graph Hot Keys Cursor Mouse Action Function Left click on graph Reposition cursor to mouse position Left drag on grap

Page 30 - 28 Analysis Tools

34 Appendices Zoom Mouse Action Function Double Click - Move - Left Click Zoom In (horizontal) Alt & Double Click - Move - Left Click Zoom In (

Page 31 - Statistics

MoTeC Appendices 35 General Mouse Action Function Right click on parameter label Show popup menu (this parameter only) Right click elsewhere Show p

Page 32 - Virtual Dash

2 Introduction  Idle Speed Control  Drive By Wire  Wide Band Lambda Sensor

Page 33 - XY Graph

MoTeC Overview 3 Overview MoTeC Interpreter is an advanced analysis tool to assist in unloading of logged data from MoTeC products and for quick, eff

Page 34

4 Overview ADL Logging Options 1MB Upgrade Upgrades the MoTeC Dash/Loggers logging memory from 384kB to 1MB. 2MB Upgrade Upgrades the MoTeC Dash/Logg

Page 35 - Appendix 1 Graph Hot Keys

MoTeC Overview 5 Telemetry Gives ‘in the pits’ viewing of real time data of a vehicle in action. Supports both continuous and ‘end of lap’ data trans

Page 36 - Keyboard

6 Software Summary Software Summary MoTeC Interpreter is designed for the Windows95/98/ME/XP® and Windows NT/2000® operating system. Note: The log

Page 37 - General

MoTeC Software Summary 7 Preferences MoTeC Interpreter has a variety of options for the analysis and display of logged data. The user can control t

Commentaires sur ces manuels

Pas de commentaire